Testing an irrigation solenoid coil with a multimeter
Testing an irrigation solenoid coil with a multimeter

How Do You Test an Irrigation Solenoid Coil?

A resistance check can help identify an open-circuit or short-circuit irrigation solenoid coil. Always compare the result with the manufacturer’s specification or a known-good coil of the same model.

What you need

  • A suitable multimeter set to resistance, shown by the ohms symbol Ω
  • The solenoid coil to be tested
  • The manufacturer’s resistance range, where available

Step-by-step check

  1. Isolate the circuit: disconnect power and separate the coil from the controller or field wiring.
  2. Set the meter: select a suitable resistance range and confirm the test leads work correctly.
  3. Measure resistance: place one probe on each coil wire.
  4. Compare the reading: use the manufacturer’s data or a known-good matching coil as the reference.

Interpreting the result

  • Expected resistance: the coil may be electrically intact, although this does not prove the valve or complete circuit works correctly.
  • Very low resistance: this can indicate a short circuit.
  • Infinite or OL: this normally indicates an open circuit.
  • Unexpected or unstable reading: inspect the leads, connections, moisture and coil condition before deciding.

Different manufacturers and coil types use different resistance values. A broad rule of thumb must never replace the specification for the exact coil being tested.

Only competent people should work on powered electrical equipment. Complete resistance checks with the circuit safely isolated.