This simplified example demonstrates units and record keeping, not a construction design.
Illustrative inflow
For an assumed 600 m² effective impermeable area and an illustrative intensity of 0.014 L/s/m², peak inflow is 8.4 L/s. The intensity is an example from Approved Document H for normal situations in England, not a universal design storm.
Illustrative volume
If a simplified constant inflow of 8.4 L/s lasted 15 minutes with no outflow, volume would be 8.4 × 900 = 7,560 litres, or 7.56 m³. Real attenuation uses a time-varying storm and simultaneous controlled outflow.
What must be added
Use the approved rainfall model, durations, climate allowance, discharge limit, control curve, storage geometry, groundwater, structural design, silt allowance and exceedance route. Verify the result independently.
Related guides
Design and compliance boundary
This page provides general UK-oriented learning, not a site design, product approval or statement of legal compliance. Confirm the requirements for the relevant UK nation, planning authority, Lead Local Flood Authority, sewerage undertaker, highway authority and environmental regulator. Use current manufacturer information and competent design. Never enter a chamber, drain or confined space without the required competent system of work.