What to Send for Technical Help

Send clear photographs, measurements and a short description of your system or problem. These help us give a useful answer and avoid unnecessary replacement parts.

Pump controls with two labelled rotary isolators and illuminated status indicators
Pump controls showing the labelled isolators and status lights.

Include these details

  • Your order number, if the query concerns an order.
  • Product name, model and SKU where available.
  • Clear overall and close-up photographs.
  • Pipe outside diameter and any printed markings.
  • Static and running pressure readings.
  • Measured flow from the source.
  • Lengths, elevation changes and a simple sketch.
  • What changed before the problem began.
  • Checks already completed.

For faults

Describe exactly what operates, what does not, and whether the issue affects one component, one zone or the complete system. Include controller messages or error codes exactly as displayed.

Safety

Do not work on live electrical equipment or dismantle pressurised components to gather information. Use a competent person where required.

Email the details to office@jkirrigation.co.uk. Use any general advice alongside the current manufacturer instructions and the requirements of your site.

Record pressure and flow clearly

State where each reading was taken and whether water was flowing. For a dynamic reading, include the measured flow at the same operating point. Do not send only a photograph of a gauge without the test conditions.

Useful one-line system summary

Use this order: water source; connection size; static pressure; measured flow and corresponding running pressure; pipe material and outside diameter; route length and elevation; valve or controller model; outlet model and quantity; symptom.

Example format: mains connection; 25 mm MDPE; 3.2 bar static; 28 L/min at 2.1 bar; 32 m route rising 4 m; four spray outlets; zone weak since filter change. Replace the example values with measured site information.

Useful photographs

  • One wide view showing the source and equipment relationship.
  • One clear image of every product label and model number.
  • Pipe markings beside a ruler or calliper reading.
  • Valve, filter and regulator flow arrows and connection order.
  • Controller display plus the station and common-wire labels, without exposing live wiring.
  • The affected area while operating, where safe.

For a product-selection enquiry

State the result required, not only the product you think you need. Include design flow, required outlet pressure, route length, elevation, water quality, electrical supply where relevant and the products already selected. This helps us assess how the proposed parts will work together before you order.

For an existing fault

Give a short timeline: when it last worked normally, what changed, which zones are affected, what readings were taken and what happened after each check. Do not replace several parts before recording the original condition.

Copy-and-complete template

Source: [mains, tank, borehole or other]
Flow and running pressure: [value, units and test location]
Static pressure: [value, units and location]
Test details: [date/time, instrument, test point, valve position and other water use]
Pipe: [material, outside diameter, route length and rise/fall]
Equipment: [make, model and SKU]
Zone: [outlet model, quantity and intended duty]
Symptom: [what happens and when]
Checks: [results already observed]
Baseline or record: [commissioning reference and any change from the previous recorded condition]

Product and SKU references

Include product links and SKUs where available. Before ordering, match the proposed parts to the required connections, flow, pressure, material and current manufacturer limits. A general description alone is not enough to identify compatible parts.

Related Irri Hub guides