Pipe Friction Loss: Darcy-Weisbach

Technical learning page. Best for engineers, designers and trade specialists who need the method, assumptions and evidence. It is not a substitute for site-specific design or current manufacturer data.

Darcy-Weisbach relates straight-pipe energy loss to pipe length, internal diameter, average velocity and a stated Darcy friction factor.

In plain English

Water loses usable pressure as it moves through pipe. The loss grows with length and velocity and is strongly affected by internal diameter. This page calculates straight-pipe loss only, so fittings, valves, filters and elevation must be handled separately.

Method

hf = fD × (L ÷ D) × (v² ÷ 2g).

hf is friction head loss in metres, fD is the dimensionless Darcy friction factor, L and D are in metres, v is in m/s and g is in m/s².

Factor convention

This page uses the Darcy factor, not the Fanning factor. The convention must always be stated. For laminar, fully developed circular Newtonian flow, the Darcy friction factor is fD = 64 ÷ Re. Turbulent closure in this foundation is supplied separately by Colebrook-White.

Assumptions and limits

This method covers straight, full pipe under the stated conditions. Fittings, valves, filters, entrances, elevation, ageing, deposits, deformation, mixed phases, transients and distributed outlet flow require separate treatment. Do not apply the full inlet flow across an entire multi-outlet lateral as though no water leaves along it.

A generic material roughness value is not approved as a product or installed-pipe default.

Worked example

Using an illustrative fixed Darcy factor of 0.02, straight length 100 m, internal diameter 0.05 m and velocity 1 m/s, the calculated head loss is approximately 2.0394 m. This is an isolated arithmetic example, not a pipe recommendation.

Evidence

The USDA NRCS National Engineering Handbook, Part 634, Chapter 4: Pipe Flow, first edition February 2022, section 634.0403, printed pages 634-4.6–9, sets out Darcy-Weisbach and the dependence of friction factor on Reynolds number and relative roughness. Equation 4-13 is the straight-pipe head-loss relationship. The chapter distinguishes implicit Colebrook-White from the explicit Swamee-Jain approximation; they are not interchangeable solver descriptions.

This is a US engineering reference. Its worked examples use US-customary units and do not supply approved roughness or performance data for an installed irrigation pipe. Supporting measured data from the US Bureau of Reclamation laboratory report retains its own measurement limitations. See Technical Sources, S46, for the inspected locations and limits.

Related Irri Hub guides