Irrigation Calculators

Use your site measurements to check flow, zone demand, application rate, approximate run time and pressure conversions.

Use these tools for initial planning. Choose equipment using current manufacturer data and the actual site conditions.

Calculation limits

These calculations provide an engineering planning estimate based on the information entered and the stated calculation method. Results depend on accurate dimensions, flow and pressure measurements, pipe condition, fittings, elevation and current manufacturer performance data. They do not replace a site survey, competent hydraulic design or manufacturer approval. Verify the completed design under actual operating conditions before purchasing or installing equipment.

Verification status: The five planning tools passed an arithmetic spot check on 14 September 2026. No named independent engineering review has been recorded, and the tools do not provide a complete hydraulic design.

Related Irri Hub guides

Explore the rainwater section


Design and field engineering


Soil, plants and irrigation scheduling

Irrigation planning calculators

Use measured inputs and consistent units. Each result shows the calculation basis and should be checked against manufacturer information and real site conditions.

Timed flow test

Enter the container volume and the measured filling time.

Formula: litres per minute = litres × 60 ÷ seconds. Repeat the test under representative running conditions.

Zone demand

Use outlets with the same flow. Calculate mixed outlet groups separately and add them.

Formula: number of outlets × flow per outlet. Use manufacturer flow at the intended operating pressure.

Application rate

Enter total delivered flow and the area receiving that water.

Formula: litres per minute × 60 ÷ square metres = millimetres per hour. This assumes perfectly even distribution.

Approximate run time

Enter the target depth and a measured or calculated application rate.

Formula: target depth ÷ application rate × 60. Adjust using site observation and distribution testing.

Pressure conversion

Convert between bar, kilopascals, psi and conventional metres of water head.

Conversions use 1 bar = 100 kPa, 1 psi = 6.894757 kPa and 1 conventional metre of water head = 9.80665 kPa.

Planning boundary

These tools do not calculate pipe friction, pump duty, sprinkler uniformity, surge, water quality, electrical requirements or installation safety. Confirm final equipment choices against current manufacturer data and the actual site.