Irrigation Design Brief and Performance Criteria

A good design brief states what success means. “Install irrigation” is not a performance requirement.

Define the outcome

  • Areas and plant types to be irrigated.
  • Required uniformity or acceptable coverage standard.
  • Watering depth, frequency and seasonal objective.
  • Maximum operating hours and permitted times.
  • Manual, automatic or remotely supervised operation.
  • Expected design life and maintenance capability.

State the boundaries

Record available water quantity, dynamic pressure, abstraction conditions, electrical supply, noise limits, access, frost exposure, public interaction and budget. Identify which information is measured, specified or assumed.

Hydraulic performance

State the required residual pressure at the critical outlet, zone flow, permitted velocity policy, pressure variation, pump operating range and maximum credible pressure. Define whether filters are assessed clean and at a permitted dirty condition.

Controls and resilience

Describe rain or moisture sensing, flow monitoring, master valves, pump interlocks, leak response, power-failure behaviour, manual override and what happens if communications fail.

Acceptance criteria

  • Measured flow and pressure for every zone.
  • Successful flushing and leakage checks.
  • Controller and protection tests.
  • Coverage or application checks where required.
  • As-fitted drawings, schedules and operator training.

Change control

Record who can approve changes. A cheaper outlet, smaller pipe or different pump is not equivalent unless the performance consequences are checked.

Related guides

Sources and limitations

This guide supports planning and record keeping. The final design must follow current manufacturer instructions, site risk assessments, legal duties, water-undertaker requirements and applicable standards. Relevant references include HSE HSG47, Water Regs UK backflow guidance and BS EN 805:2025.