Equipment, Pumps and Irrigation Controls: Start Here

Choose pumps and controls from the required flow, pressure and operating sequence. Start with the guides below for pump sizing, valve control, fault detection and system protection.

Irrigation pump set installed in a pump room
An installed irrigation pump set and associated controls.

Choose the route that matches the job

Question Start here
What pump duty is required? Which irrigation pump do I need?, then total dynamic head and pump and system curves.
How should field valves be controlled? Conventional multicore or two-wire decoder control and solenoid-valve identification.
How does the pump or mainline start safely? Master valves, pump-start relays and interlocks.
How is abnormal flow detected? Flow sensing and high-flow shutdown.
How is the pump protected? Dry-run protection, pressure vessels and cycling, and variable-speed drives.
Is resilience required? Duty and standby pump sets.
Is this an electrical or programming issue? UK supply identification, electrical safety, controller programming and the safe symptom guide.

Minimum design record

  • Measured design flow in litres per minute or cubic metres per hour, and required pressure or head at the duty point.
  • Water source, suction conditions, water quality, filtration and backflow arrangements.
  • Pump curve, motor nameplate, supply details, protection settings and permissible starts per hour.
  • Controller type, station schedule, valve/decoder addresses, cable routes and waterproof-joint records.
  • Normal station flows, alarm thresholds, master-valve or pump logic, and the tested shutdown response.

Compare pumps and controllers

Compare the pump against the measured flow and head, source and installation arrangement. Match the controller to the station count, enclosure, wiring and control logic.

See tanks and pumps · See landscape controllers

Manufacturer instructions and electrical safety

Use the exact manufacturer manuals alongside HSE guidance on electrical isolation and competence. Product-specific terminal ratings, protection and commissioning values must not be generalised.

Safety and scope

Do not select equipment from pipe size alone. Do not connect a controller output directly to a mains-voltage pump. Electrical design, isolation, testing and work in wet locations require competent persons. A controller, relay or drive is not a substitute for hydraulic protection, backflow protection, pressure relief or the exact manufacturer instructions.

Site-specific design: use these guides to plan the equipment checks. It does not specify a product, cable size, protective device, pressure-vessel volume or control setting for an unmeasured site.