Use this guide to investigate a pump that starts and stops too often, fluctuates around a set pressure or cycles when no irrigation demand is expected.
A pressure vessel stores a limited volume of pressurised water. Its nominal shell volume is not the same as usable drawdown. A vessel can reduce starts caused by small intermittent demand, but it cannot correct a leak, passing valve, unsuitable pump, unstable sensor or incorrect control sequence.

Stop first if the condition is unsafe
Isolate and obtain competent help for repeated protective-device operation, overheating, a stalled or noisy motor, damaged electrical equipment, uncontrolled pressure, severe vibration, loss of water supply or a failed relief arrangement. Do not keep resetting or restarting the equipment.
Record the cycling pattern
- Pressure at each start and stop.
- Run time, stopped time and starts over a representative period.
- Measured flow and which zone or outlet is active.
- Whether cycling continues when no irrigation demand is intended.
- Pump, vessel, controller, pressure switch, transducer or drive model and displayed alarms.
- What changed before the symptom began.
Use the pattern to choose the route
| Observation | Check next |
|---|---|
| Cycling while no demand is intended | Passing zone or master valve, leak, check-valve leakage, hidden outlet, controller command or pressure loss from the system. |
| Very short run and stopped periods at small demand | Usable vessel drawdown, pre-charge procedure, isolation, control differential, minimum pump run time and actual small demand. |
| Pressure signal jumps or the drive hunts | Sensor location, air, wiring, scaling, control parameters, minimum flow and hydraulic instability, using the exact drive instructions. |
| Cycling appears only on one zone | Compare that zone demand with pump output and control limits; check the zone valve, outlets and measured flow. |
| Pump runs but cannot reach stop pressure | Leak or open demand, source and suction condition, pump duty, restrictions, rotation after electrical work and stop setting. |
| Pump trips or does not run | Safe pump electrical symptom guide. |
Separate hydraulic and control faults
If pressure falls with no intended demand, isolate branches in a controlled manner where the design permits and record which isolation changes the result. This can locate a leak or passing route without altering controller settings. If the hydraulic pressure is stable but the pump command changes, investigate the pressure switch, transducer, controller, drive, wiring and programmed thresholds through competent testing.
Do not adjust several pressure or drive settings at once. Save the original values and change only settings authorised by the installed documentation.
Pressure-vessel checks
- Use the manufacturer's drawdown table or approved sizing method for the actual pre-charge, cut-in and cut-out pressures.
- Check pre-charge only by the specified method, normally with electrical isolation and the water side safely at zero gauge pressure.
- Confirm the vessel pressure rating, orientation, potable or non-potable suitability and relief arrangement.
- Do not assume a vessel marked 100 litres provides 100 litres between pump starts.
- A waterlogged, isolated, incorrectly charged or undersized vessel can reduce useful drawdown, but prove the condition before replacing it.
Variable-speed and specialist systems
Variable-speed systems may use a vessel mainly for stability and transient damping, while some pump models have controls designed for frequent restarting. Manufacturer limits differ. Grundfos, for example, states that its SQ/SQE range has model-specific soft-start behaviour; that statement must not be applied to other pumps. Use the exact pump and controller instructions for permitted starts, minimum run time and vessel requirements.
What to record during commissioning
- Pump duty point, measured flow and pressure.
- Control start and stop thresholds or pressure setpoint.
- Vessel model, nominal volume, rating and verified pre-charge method.
- Cycle times at no intended demand, small demand and a representative irrigation zone.
- Result of leak and valve-isolation checks.
Sources and limitations
- Lowara variable-speed booster-set technical catalogue
- Grundfos SQ/SQE model-specific switching guidance
- HSE guidance on isolation and competence
Vessel volume, pre-charge and control settings cannot be selected safely without the pump duty, system pressure range and manufacturer data.
Back to Irrigation Fault Finding | Night-flow leak testing | Equipment, pumps and controls