Irrigation Water Quality Testing and Interpretation

Why test: Clear water is not necessarily suitable water. Chemistry, suspended solids and biological contamination can affect plants, soil, drippers, sprinklers, filters, pumps and public safety.

Build the test around the use

Risk Useful information Possible effect
Salinity Electrical conductivity and dissolved salts Crop stress, soil accumulation and leaf damage.
Alkalinity and pH Bicarbonate/alkalinity and pH Deposits, nutrient availability and treatment demand.
Iron and manganese Dissolved and total concentrations where appropriate Oxidised deposits, staining and emitter blockage.
Suspended solids Turbidity, suspended solids and particle character Filter load, abrasion and blockage.
Biological risk Tests selected for source, crop, reuse and exposure Plant disease, biofilm or human-health concerns.
Specific ions Sodium, chloride, boron and nutrients where relevant Crop-specific toxicity or soil-structure problems.

Sampling plan

  1. Agree the analysis and bottles with an appropriate laboratory before sampling.
  2. Choose locations representing the source, after treatment and at the application point where needed.
  3. Flush the sampling point as instructed and avoid contaminating the bottle or cap.
  4. Record date, time, source condition, treatment status and recent rainfall.
  5. Keep, preserve and deliver samples exactly as the laboratory instructs.
  6. Compare results with the crop, soil, irrigation method and equipment limits.

Brief the laboratory before taking the sample

  • State the source, irrigation use, crop or turf, soil/substrate, application method, public or worker exposure and the problem being investigated.
  • Ask which raw, post-treatment and application-point samples are required, and whether seasonal or event-based samples are needed.
  • Use the laboratory's supplied bottle, preservation, temperature and delivery instructions; record chain of custody where the decision requires it.
  • Request units, analytical method, detection/reporting limits and interpretation appropriate to the intended use.
  • Record treatment status, filter condition, source level/flow, recent rain, temperature, colour/odour and anything changed before sampling.

AHDB’s horticulture guidance suggests at least annual, and sometimes six-monthly, analysis as a sector baseline, especially for a new source or equipment investment. That is not a universal interval for every irrigation use. Increase or alter sampling according to source variability, exposure, treatment, licence, assurance scheme, crop/turf and equipment risk.

One sample may not represent the season

Ponds and rivers can change after rainfall or algal growth. Boreholes can change with pumping and aquifer conditions. Reused water can change with production cycles. Set a review frequency based on risk and investigate sudden changes in colour, smell, filter loading, deposits or crop response.

Do not select treatment from one number

Acid dosing, chlorination, oxidation and other chemical treatments can create serious hazards and alter several water characteristics. They require competent design, control, verification and compliance. Filtration removes particles but does not automatically correct dissolved salts or disinfect water.

AHDB framework

AHDB recommends considering chemical composition, suspended solids and plant pathogens. It notes that poor water can shorten equipment life, clog irrigation systems and affect crop growth and quality.

Related Irri Hub guides

Sources and limitations

See AHDB water-quality guidance. Laboratory interpretation and acceptable limits must be matched to the actual crop, soil, exposure and equipment.