How to Read Pump Curves and System Curves

Technical guidance: Always use the curve for the exact pump, impeller, speed and power supply.

Dual vertical irrigation pump set with control equipment
An installed pair of vertical irrigation pumps with controls.

A pump curve describes what a pump can produce. A system curve describes what the pipework and irrigation system require. Their intersection is the expected duty point.

The pump curve

A centrifugal pump curve normally plots flow horizontally and head vertically. Head usually falls as flow increases. The left-hand end near zero flow is shut-off head. It must not be treated as the pressure available at the design flow.

Manufacturer charts may also show efficiency, absorbed power, impeller diameter, speed and net positive suction head required. Check that the chart matches the exact model and operating frequency.

Record the curve identity

Save the manufacturer, complete model and suffix, article code, supply frequency, speed or control mode, impeller where applicable, document number, revision and issue date with every curve used. If the label and curve cannot be tied to the same product revision, treat the selection as unresolved.

Record P1 and P2 using the manufacturer's definitions. Do not substitute one for the other or merge values from a current manual, a legacy label and a reseller listing.

The system curve

The system curve combines static head with flow-dependent losses. A simplified representation is:

Hsystem = Hstatic + KQ²

This square relationship is a useful approximation for turbulent flow in a fixed system. The exact curve depends on the chosen friction method, pipe properties, fittings, valves and equipment. Required outlet pressure must also be included.

The duty point

The expected operating point is where the pump curve and system curve cross. At that point, the head produced by the pump equals the head required by the system. Opening or closing zones changes the system curve and therefore changes the operating point.

Worked reading example

Assume an irrigation system requires 32 m head at 20 L/min, 40 m at 35 L/min and 52 m at 50 L/min. A candidate pump curve shows 55 m at 20 L/min, 44 m at 35 L/min and 30 m at 50 L/min.

If both curves are linearly interpolated between the stated 35 and 50 L/min points, they cross at approximately 37.3 L/min and 41.8 m head. This is a teaching estimate from the stated points, not a measured duty or a substitute for a full manufacturer curve. It would be wrong to combine separate maximum flow and head figures into one operating point.

What changes the operating point?

  • Opening more outlets increases required flow and usually system loss.
  • Closing a valve adds resistance and moves operation towards lower flow.
  • A dirty filter adds loss.
  • Changing pipe diameter changes the system curve.
  • Variable-speed control changes the pump curve.
  • A falling tank or borehole water level increases static lift.

Checks before selecting a pump

  1. Define the required flow for each operating condition.
  2. Calculate total dynamic head at those flows.
  3. Plot or tabulate the system requirement.
  4. Use the exact manufacturer curve.
  5. Check efficiency and motor power near the duty point.
  6. Check minimum and maximum flows, pressure limits and suction requirements.
  7. Confirm controls prevent damaging operation, including dry running or excessive cycling.

Variable-speed pumps

Reducing speed generally reduces flow, head and power, but affinity-law estimates require care where static head is significant. A controller does not remove the need to understand the system curve or the pump’s permitted operating range.

Related Irri Hub pages

Sources and limitations

The US Department of Energy pumping systems sourcebook, PDF pages 40–41, explains the head/flow relationship, best efficiency point and need for the exact impeller curve. The Grundfos pump-curve module, printed pages 1–5, distinguishes QH, efficiency, NPSH and power curves, including P1 and P2. These are method sources, not approval of a Stockist product. The exact manufacturer's current curve and permissible operating region remain controlling.