How to control drip irrigation

Choose a tap timer for a simple system off an outside tap, a battery controller for separate valves where there is no mains power, or a wall-mounted controller for a permanent wired installation.

Battery tap timer

One or two watering zones directly from an outside tap.

Battery controller and valves

A separate controller wired to compatible 9 V DC latching solenoids.

Wall-mounted controller

A Hunter X2 and a wired 24 V AC valve box, or an XC Hybrid with DC latching outputs.

Match the coil to the controller’s valve output. Battery valve controllers generally use a 9 V DC latching solenoid, which opens and closes on a short electrical pulse. The Hunter X2 uses 24 V AC solenoids. The two coil types are electrically different, even when the valve bodies look alike.

Battery tap timers for one or two zones

A tap timer screws onto a suitable outside tap and contains its own valve. The Hunter BTT-101 has one outlet. Choose the Hunter BTT-201 for two outlets with separately programmed schedules. Set the start times and run times in the Hunter BTT app while within Bluetooth range. The timer then follows its schedule on its own.

Hunter BTT-201 tap timer with two independently controlled outlets

Hunter BTT-201 two-outlet Bluetooth tap timer

For a complete kit, choose the above-ground drip kit with phone control or the below-ground drip kit with phone control. Check the tap thread, available flow and running pressure, and the filtration and regulator specified for your dripline.

Battery controllers with separate 9 V valves

One valve with the Hunter NODE-BT

The Hunter NODE-BT-100 one-station controller comes with a Hunter DC latching coil. Fit it to a compatible Hunter valve, or choose the Hunter PGV 1-inch BSP valve in its 9 V DC latching configuration. The one-station NODE-BT controls one valve independently.

Up to four valves with the Rain Bird ESP-BAT-BT

Choose the four-station version of the Rain Bird ESP-BAT-BT for up to four separately controlled drip zones without a mains supply. A compact option is the Antelco eZyvalve 4 with 9 V DC latching valves. Check the combined controller and valve setup before burying the box. Wire one station per valve and follow both manufacturers’ common-wire and polarity instructions. Test opening and closing on every outlet. Some third-party latching coils can trigger a Rain Bird wiring warning even when operating, so check the joints and confirm valve operation using the Rain Bird troubleshooting instructions.

Hunter NODE-BT battery controller installed in a valve box

Hunter NODE-BT for one field valve

Rain Bird ESP-BAT-BT four-station battery controller

Rain Bird ESP-BAT-BT four-station controller

Antelco eZyvalve 4 with the lid removed, showing the four 9 V latching valves

Antelco eZyvalve 4 in the 9 V DC latching version

Add a rain shut-off switch. The ESP-BAT-BT has a dedicated yellow sensor circuit. Leave the factory sensor link in place when no sensor is fitted. For a compatible wired sensor such as the Rain Bird RSD-BEX, replace the factory sensor link with the sensor leads as shown in the Rain Bird setup instructions. The sensor can prevent scheduled starts during wet weather.

Shop 9 V DC latching valves and coils

Check the controller model, the valve body and the exact coil part number together. The coil must fit the valve body and match the controller’s latching pulse. For a very small drip zone, check the valve’s minimum flow before ordering.

Hunter irrigation valve solenoid

Hunter replacement latching coil

Rain Bird low-flow valve showing the 9 V markings and wire leads

Rain Bird ¾-inch low-flow valve with a 9 V latching solenoid

Toro parts and assemblies for existing systems

For a compatible higher-flow installation, see the Toro P220G DC latching valve range, P220 DC coil and regulator, and our single-valve and dual-valve stainless-steel DC assemblies. Check the controller’s support for the exact coil and the valve’s minimum flow. These larger valves are intended for higher-flow systems.

Wall-mounted controllers and multicore cable

The Hunter X2 four-station controller runs conventional 24 V AC valves. Run one switched core per zone and one shared common. A three-zone box needs at least four cores, and a four-zone box needs at least five. Allow additional cores if the layout also uses a master valve or spare circuits.

Pair it with our pre-assembled Hunter three-valve box, Hunter four-valve box or the compact 24 V AC Antelco eZyvalve 4. The optional Hunter WAND module adds Hydrawise control over Wi-Fi. For a wall-mounted setup that needs DC latching valves, the Hunter XC Hybrid is the Hunter option. Its station output remains DC latching when the optional plug-in supply is used.

Hunter X2 four-station wall-mounted irrigation controller

Hunter X2 wall-mounted controller for 24 V AC valves

Before you order

  1. Count the areas that need independent watering and decide whether a tap timer or separate valves suit the layout.
  2. Measure the available flow and pressure while the water is running, and check each zone against the valve, filter, regulator and dripline specifications.
  3. Match the output on the controller to the valve coil. Follow the wiring diagram and use waterproof connectors in a valve box. Use a competent person for fixed mains electrical work.
  4. Run and flush each zone before closing the ends. Check that each valve fully shuts and that the smallest zone runs cleanly.

See also choosing dripline, controller programming and rain sensors, and the Irri Hub technical library.