Plain-English definitions for common irrigation, pipework and water-system terms. Product specifications and manufacturer instructions take priority where terminology differs.
Backflow prevention
Measures used to stop potentially contaminated water flowing back into a clean supply. Requirements depend on the water source, risk and applicable regulations.
Bar
A unit of pressure. As a rough static-water approximation, about 10 metres of vertical water head corresponds to about 1 bar.
Controller
The device that starts irrigation zones according to a programme or instruction. It may operate valves directly or communicate through decoders.
Decoder
An addressed field device used in a compatible two-wire control system to operate a valve or other component.
Dripline
Pipe with emitters built into it at regular spacing. Products differ by diameter, emitter flow, spacing, pressure compensation and suitability for surface or subsurface use.
Dynamic pressure
Pressure measured while water is flowing. It is normally more useful than static pressure when checking what an irrigation zone can actually receive.
Emitter
A small outlet that applies water at a stated rate under specified conditions. Emitters can be built into dripline or fitted separately.
Flow rate
The volume of water moving in a given time, commonly litres per minute or cubic metres per hour.
Foot valve
A non-return valve, usually with a strainer, fitted at the lower end of a pump suction line to help retain prime and exclude debris.
Friction loss
Pressure lost as water moves through pipe, fittings, valves and equipment. Loss increases with flow and is greater in smaller or more restrictive routes.
Head
A way of expressing the energy or pressure a pump must provide, commonly stated in metres. Pump selection uses the required flow at the total head.
Imperial PVC
A PVC size family described by nominal imperial sizes. The nominal description is not the same as the measured outside diameter.
Lateral
A branch or run carrying water to outlets, such as a length of dripline or a pipe serving sprinklers.
LDPE
Low-density polyethylene pipe, commonly used for micro-irrigation distribution and small take-offs in appropriate applications.
MDPE
Medium-density polyethylene pipe. Blue MDPE is commonly used for suitable potable-water services with approved fittings and installation practice.
Mesh
One method of describing filter-screen fineness. Do not assume mesh numbers translate directly between every filter type; use the downstream product requirement.
Non-return valve
A valve intended to permit flow in one direction and resist reverse flow. It is not automatically a compliant backflow-prevention device for every application.
Pressure-compensating emitter
An emitter designed to maintain a more consistent output across a stated pressure range. Installation limits still apply.
Pressure regulator
A device that reduces and controls downstream pressure within its stated inlet-pressure and flow range. It cannot increase insufficient supply pressure.
Prime
The condition in which a surface pump and its suction route contain the water needed for the pump to establish flow. Air entry or a failed non-return valve can cause loss of prime.
Rotor
A rotating sprinkler used for suitable turf and landscape areas. Models differ in radius, flow, trajectory, nozzle and operating pressure.
Solenoid valve
An electrically operated valve that controls an irrigation zone. Voltage and controller compatibility must be checked.
Static pressure
Pressure measured when no water is flowing. It does not show the pressure available at the required flow rate.
Suction lift
The vertical distance a surface pump must lift water on its inlet side, assessed from the operating water level. Practical suction capability is limited by site and pump conditions.
Swing joint
A flexible or articulated connection between a lateral pipe and a sprinkler, used to aid positioning and reduce stress.
Valve box
An accessible enclosure around buried valves or other serviceable components. It should permit inspection and maintenance without unnecessary excavation.
Water hammer
A pressure surge caused by a rapid change in water velocity, such as a fast-closing valve. System design and operating speed influence the risk.
Back-siphonage
Reverse flow caused when pressure in the supply falls below the pressure downstream. The required protection depends on the applicable fluid category and installation.
Backpressure
Reverse flow caused when downstream pressure becomes greater than supply pressure. Not every backflow device protects against both backpressure and back-siphonage.
Design capacity
The flow selected for design together with the pressure available at that flow. It must be tied to a defined test point and operating condition.
Flow control
An adjustment on some valves used to limit flow or influence valve operation. It is not a substitute for a correctly selected pressure regulator.
Master valve
A normally closed valve controlling the shared irrigation mainline, commonly operated with the active zone. Its compatibility and operating sequence must match the controller and system design.
Precipitation rate
The depth of water applied over an area in a given time, commonly millimetres per hour. Outlet spacing and distribution affect the actual application.
Station
A controller output assigned to operate a zone valve or compatible field device. Station numbering should match the site record and valve labels.
Zone
A group of compatible irrigation outlets operated together. Its total demand must remain within the available flow and pressure.