pH, Alkalinity and Acid Dosing for Irrigation Water

pH describes current hydrogen-ion activity; alkalinity describes acid-neutralising capacity. Water with similar pH can require very different acid quantities. pH alone must not determine a dose.

Information required

  • Accredited or competent analysis of pH, alkalinity/bicarbonate, hardness, conductivity and relevant nutrients.
  • Crop, soil or substrate target and the acceptable treated-water range.
  • Acid identity, concentration, density, nutrient contribution and safety data sheet.
  • Maximum and minimum system flow, injection-point mixing and contact time.
  • Compatible pump, tank, seals, pipework, injection valve and monitoring instruments.

AHDB's water-quality guidance explains that alkalinity influences treatment need and that nitric acid contributes nitrogen which must be included in the fertiliser calculation.

Controlled dosing sequence

  1. Use a laboratory or competent agronomic method to determine the neutralisation requirement.
  2. Confirm the chemical calculation independently and undertake a controlled jar or pilot test where appropriate.
  3. Interlock dosing with proven water flow and stop on loss of flow, low tank level, sensor fault or excessive treated-water deviation.
  4. Measure treated water at a point with adequate mixing delay.
  5. Retest the water and review the crop or soil response.

No generic worked dose

This page intentionally does not provide a universal litres-of-acid formula. Commercial acids vary in concentration and density, alkalinity may be reported in different equivalent units, reactions can release heat, and overdosing can injure people, plants and equipment.

Safety boundary: acid handling and dosing require a site-specific COSHH assessment, trained personnel, secondary containment, compatible PPE, ventilation, emergency arrangements and strict separation from incompatible chemicals. Follow HSE COSHH guidance.

Assumption and limitation: changing pH does not automatically solve salinity, pathogens, suspended solids, iron or manganese. Specialist water-treatment and agronomic advice may be necessary.

Related: water-quality testing and treatment commissioning record.