Rainwater Harvesting System Fault Finding

Best for: Users and service staff gathering safe evidence before repair. Isolate electrical and pressurised equipment before intrusive work.

Start by separating four questions: is water reaching the tank, is usable water available, can the pump move it, and can it pass through the distribution system? Changing several settings at once makes the cause harder to prove.

Low-profile rectangular Enduramaxx water tank with a top access lid and connection
A low-profile water storage tank with a top access lid.

Tank not filling

  • Confirm rainfall actually reached the collection surface.
  • Inspect gutters, downpipes, diverters and pre-filters for blockage or bypass.
  • Check whether the inlet or overflow is incorrectly connected.
  • Look for leakage, a stuck valve or false level indication.

Pump will not start

  • Check safe external indications and controller alarms.
  • Confirm the low-level device is not correctly preventing dry running.
  • Check permitted isolators and protective devices without repeatedly resetting a fault.
  • Use a competent person for electrical testing or enclosure access.

Pump runs but pressure is low

  • Record tank level, pump pressure and zone flow.
  • Check inlet restriction, air entry, blocked filters and closed valves.
  • Compare the operating point with the pump curve.
  • Check whether several zones or outlets are operating unexpectedly.
  • Investigate suction conditions and cavitation symptoms.

Rapid cycling

Look for very small demand, leakage, incorrect pressure-vessel pre-charge, failed non-return valve, unsuitable controller settings or a pump operating outside its intended range. Do not adjust a pressure vessel while it is pressurised.

Dirty water or blocked emitters

Inspect collection and storage before repeatedly replacing final filters. Record sediment, algae, odour and debris. Check that tank draw-off avoids settled or floating contamination and that the filter rating matches the downstream equipment.

Overflow or flooding

Check the overflow is clear, correctly sized, screened and routed to an appropriate destination. Confirm that a backflow-prevention air gap or weir has not been altered or obstructed. Do not seal an overflow to stop visible discharge.

Unexpected mains-water use

Check the tank-level sensor, top-up control and leakage. Do not bypass an air gap or connect supplies directly. Record meter readings over a defined period and isolate the investigation from normal site demand where possible.

Information for technical support

  • System drawing and photographs of safe external components.
  • Tank level and recent rainfall.
  • Pump, controller and filter models.
  • Flow and dynamic pressure readings.
  • Alarm codes and the exact operating sequence.
  • Maintenance history and the last known correct operation.

Related Irri Hub guides

Sources and limitations

Use the manufacturer's fault procedure and maintenance instructions. See BS EN 16941-1:2024 and Water Regs UK's alternative-water guidance. This page does not replace competent electrical, structural, water-quality or regulatory assessment.