Paving should shed water away from buildings and towards a lawful, adequately designed destination.
Surface falls
For common situations in England, Approved Document H recommends at least 1:60 on impervious surfaces and states that crossfall on a path should not exceed 1:40. It also describes a reverse gradient for at least 500 mm where levels might otherwise concentrate water against a wall.
Capture and silt control
Place channels or gullies at genuine low points and size them for the drained area and design rainfall. Provide measures such as suitable gully pots or catchpits to keep silt and grit out of downstream pipework.
Safe exceedance
Plan where water will go if an inlet blocks or the design storm is exceeded. Avoid directing it into buildings, neighbouring land, unsafe pedestrian routes or contaminated areas.
Related guides
Important boundary
This is general UK-oriented guidance, not a drainage design or confirmation of compliance. Requirements differ across England, Wales, Scotland and Northern Ireland and may also depend on planning conditions, the approving body, sewerage undertaker, highway authority, environmental regulator, site risk and current standards. Use the approved design, current manufacturer instructions and competent advice. Never enter a drain, sewer or confined space.