Turbulent Friction Factor: Colebrook-White

Technical learning page. Best for engineers, designers and trade specialists who need the method, assumptions and evidence. It is not a substitute for site-specific design or current manufacturer data.

Colebrook-White is an empirical correlation used to find a Darcy friction factor for turbulent flow in a full circular pipe when Reynolds number and relative roughness are specified.

In plain English

Colebrook-White estimates the friction factor needed by Darcy-Weisbach for turbulent full-pipe flow. It needs Reynolds number and justified pipe roughness, so it belongs after those inputs have been established.

Method

1 ÷ √fD = -2 log10(ε ÷ (3.7D) + 2.51 ÷ (Re√fD)).

fD is the Darcy friction factor, ε is equivalent roughness, D is actual internal diameter and Re is Reynolds number. The logarithm is base 10. The equation is implicit, so the factor appears on both sides and must be solved iteratively.

Validation and limits

For this page, the calculation is limited to turbulent candidate flow above Re 4000 and relative roughness from zero to 0.05. Laminar and transition flow are rejected. A solution must have valid inputs, a bracketed positive root, convergence and a residual check. The last numerical iterate must not be returned as valid after non-convergence.

An accurately solved root is still a result from an empirical correlation using supplied inputs. It does not verify the actual roughness or condition of a pipe.

Worked checks

Calculation checks include a constructed smooth case at Re 2,510,000 that gives fD = 0.01, a constructed rough case that gives 0.04, high-precision root comparisons and residual tests. These checks are not manufacturer performance data.

Evidence

The modern equation was visually checked in Penn State ME320 Lecture 21, PDF page 2, in the recorded 10 October source audit. The lecture's separate PVC worked example remains excluded because its roughness values conflict on PDF pages 4–5. The original 1939 equation page remains unverified.