A pump should be selected from the flow and pressure required at the duty point, not from motor power alone.

What to send for a pump-selection enquiry
- The required flow and residual pressure for every zone that may run, including combinations.
- The lowest expected source-water level and the height of the critical outlet, both measured from the same datum.
- Suction and delivery pipe lengths, outside diameter, SDR or internal diameter, fittings, valves, filters and known restrictions.
- Water source, temperature, likely debris or solids, water-quality results and any abstraction or supply restrictions.
- The exact pump curve or nameplate photograph if a pump already exists, plus voltage, phase and control arrangement.
- Whether the requirement is normal duty, peak duty, duty/assist or resilience after a stated failure.
These details allow a duty point to be compared with an exact pump curve. Motor power, connection size, maximum head and maximum flow cannot establish suitability on their own.
Read the pump curve
The useful selection point is where the required flow meets the total head. Total head includes static lift, elevation and friction losses. Maximum flow and maximum head are normally opposite ends of a curve and should not be treated as one operating point.
Surface or submersible?
Surface pumps require a reliable flooded or primed suction arrangement within their stated suction limits. Submersible pumps work within the water source and can be useful where suction lift would be difficult. The correct choice depends on the site and water quality.
Pump and electrical installation should follow the manufacturer's instructions and applicable regulations. Send us the collected information for product-selection help.
Prepare a duty-point sheet
State the required flow and pressure at the critical outlet, then work back to the pump. Convert the required outlet pressure to head and add elevation, pipe and component losses. Record both the normal design duty and any credible minimum or maximum operating condition.
- Required zone flow.
- Required residual pressure at the outlets.
- Suction lift or inlet pressure at the lowest source level.
- Discharge elevation to the highest critical outlet.
- Losses through pipe, valves, filters, regulators and other equipment.
- Expected variation as filters load, water level changes or zones differ.
Check the whole curve, not one headline figure
Plot the required duty against the manufacturer's current pump curve for the exact model and speed. Check that the expected operating range stays within the permitted region and that the motor, seals and materials suit the water and duty. A pump selected near shut-off or maximum-flow extremes can be inefficient, unstable or unsuitable even when a catalogue headline appears adequate.
Suction conditions and cavitation
A surface pump needs sufficient inlet pressure after suction lift and suction-pipe losses. Air leaks, excessive lift, restrictions, warm water or insufficient available suction head can cause noise, loss of performance and cavitation damage. Check the manufacturer's priming and net positive suction head requirements. Do not use a theoretical atmospheric suction limit as a practical design allowance.
Controls and protection
Confirm how the pump starts and stops, what happens when every valve closes, and how dry running, overload, leakage and rapid cycling are handled. Check vessel sizing, pressure-switch settings, variable-speed controls, level protection, non-return valves and electrical protection as applicable. Electrical selection and installation must be completed by a competent person.
Product and SKU references
Use the exact product link and SKU when comparing pumps. Check the required flow and total head, connections, power supply, materials, controls and current manufacturer limits before ordering. A generic pump description or motor rating does not confirm suitability.
Related Irri Hub guides
- Total dynamic head
- Pump curves and system curves
- Pump suction, cavitation and NPSH
- Pump will not prime
Electrical supplies and rainwater
Explore the rainwater section
Electrical information before pump selection
Explore irrigation water sources
- Choosing an irrigation water source
- Boreholes and wells for irrigation
- Ponds, lakes, rivers and streams
- UK water abstraction rules
- Irrigation water quality testing
- Mains break tanks and alternative water
- Water intakes, screening and pump protection
Match the exact product revision
A model-family name is not enough for a final selection. Record the manufacturer article code, complete suffix, GTIN where available, nameplate revision or manufacture date, supply, P1 electrical input, P2 motor output and the reference/revision of the curve used. Similar-looking 900, 900 A and 900 X variants can have different controls or inlets.
Do not combine a current family curve with a legacy nameplate or reseller power figure unless the article and revision match. Maximum head and maximum flow are usually separate ends of the curve; neither proves the required duty point.
Examples to inspect after the design checks
These catalogue examples are for identification and comparison only. Confirm the exact duty, connections and manufacturer data before ordering. Neither card is matched to the 48.6 m at 40 L/min teaching example on the TDH guide. A model must meet the required flow and head together on its exact revision’s curve.

DAB Divertek 650 A
Catalogue example: DAB DIVERTEK 650 A, 230 V automatic submersible pump; catalogue SKU 60203222. Confirm the current DAB article code, label and duty curve before selection. The catalogue power figure has not been verified as electrical input.

DAB Divertron 900
Catalogue example: DAB DIVERTRON 900 automatic submersible pump; internal Stockist SKU DABDVTRN0900. Confirm the DAB article code, complete suffix, label and current duty curve before selection. The current/legacy power-rating discrepancy remains unresolved.