Dripline Zone Flow Worked Example

This metric example shows emitter counting, zone flow and application rate without selecting a real product.

Illustrative layout

Assume eight 30 m laterals with emitters at 0.30 m spacing. Approximate emitter count is 8 × 30 ÷ 0.30 = 800 emitters, subject to exact end positions.

Illustrative flow

At an assumed 1.6 L/h per emitter, total demand is 800 × 1.6 = 1,280 L/h, equal to 1.28 m³/h or about 21.3 L/min.

Illustrative application

If those laterals serve 240 m², average application is 1,280 ÷ 240 = 5.33 mm/h. Real design must confirm manufacturer limits, pressure, levels, wetting pattern, filtration and measured supply.

Related Irri Hub guides

Design boundary

This is general UK-oriented irrigation guidance, not a site design or a substitute for the selected manufacturer’s current data. Confirm measured dynamic pressure, available flow, levels, water quality, soil, planting and local requirements. Do not mix figures from different product families. Electrical work and contaminated or non-potable water require the appropriate competent assessment.