Best for: Engineers, trade professionals and readers who want to inspect the evidence behind the hydraulic learning pages.
This source register identifies the accountable publications used by the current hydraulic foundation. A listing confirms the source identity and recorded use; it does not mean that every statement in the publication has been independently approved.
- S01: FAO, Handbook on Pressurized Irrigation Techniques, 2007, Chapter 4, printed p.4.5.
- S02: US Department of Energy, DOE-HDBK-1012/3-92, Thermodynamics, Heat Transfer, and Fluid Flow, Volume 3, June 1992, selected equations and pp.32–33 worked example.
- S03: NASA Glenn Research Center, Bernoulli's Equation, mathematical explanation and assumptions.
- S04: NIST, Guide to the SI, Special Publication 811, Appendix B.8, reference constants and conversions.
- S05: NIST SP811, Chapter 5, minute, hour and litre definitions.
- S06: NIST SP811, Chapter 4, SI prefix definitions.
- S07: Pennsylvania State University, John M. Cimbala, ME320 Lecture 21, Spring 2015. The modern Colebrook equation was visually inspected on PDF page 2 in the recorded source audit; the separate example's tenfold roughness mismatch on PDF pages 4–5 remains excluded. This is modern method evidence, not verification of the original historical equation page or a particular pipe product.
-
S08: US EPA, EPANET 2.2 User Manual. Current online section 3.1, Pipes and section 12.1, Pipe Resistance Coefficient were checked for regime handling, new-pipe roughness scope and the distinction between the Swamee-Jain approximation and an implicit Colebrook-White solution. Official public code provenance was checked 21 October 2026: the EPA archive release page identifies tag 2.2.0 at commit
6d7f5f9c08048ce6b25bb64340547446362ec389; the repository README describes the archive as source and documents for the official 2.2.0 release; the engine-folder README identifies the solver source as v2.2.0. In the current official archive source,SRC_engines/src/solver/hydcoeffs.c,DWpipecoeff()handles the laminar branch at Re ≤ 2000 andfrictionFactor()labels the Re ≥ 4000 branch as the Swamee-Jain approximation, with Dunlop interpolation for 2000 < Re < 4000. This establishes a public release identity and source-code locator with high-level regime agreement; it is not a reproducible-binary audit or line-by-line validation of the archived printed equations. A bounded official-source check on 25 October 2026 also inspected the repository's currentUser_Manual/docs/12_analysis_algorithms.rstand its rendered section 12.1. Both current online forms state the laminar branch as Re < 2,000 withf = 64/Re, the Swamee-Jain branch as Re > 4,000 with a 0.25-over-log-squared expression, and the transition branch as 2,000 < Re < 4,000 withX4nested in the cubic interpolation. This gives an accountable current-document reference distinct from the packaged static 2.2.0 PDF. No standalone official erratum for that static PDF was located in the bounded repository/documentation check, so the recorded visual audit's issues in archived section 13.1, printed pages 111–112, remain a static-PDF presentation hold. Exact archived equation transcription and product-specific roughness values remain withheld. - S09: Royal Society, Osborne Reynolds, 1883 investigation of direct and sinuous water motion and resistance in channels. Publisher metadata checked.
- S10: Royal Society, C. F. Colebrook and C. M. White, Experiments with fluid friction in roughened pipes, 1937. Publisher metadata checked.
- S11: Bibliothèque nationale de France catalogue, Daniel Bernoulli, Hydrodynamica, 1738. Catalogue metadata only.
- S12: BnF Catalogue collectif de France, Henry Darcy, Recherches expérimentales relatives au mouvement de l'eau dans les tuyaux, 1857. Catalogue metadata only.
- S13: IAPWS, Release on the IAPWS Formulation 2008 for the Viscosity of Ordinary Water Substance, sections 2.4, 2.6–2.8 and 4. Table 4 supplies eleven simplified checks with critical enhancement omitted; Table 5 supplies six separate near-critical checks. The recorded isolated Table 4 arithmetic audit does not establish a deployed calculator, thermodynamic-state service or verified near-critical implementation.
- S14: Glenn O. Brown, The History of the Darcy-Weisbach Equation for Pipe Flow Resistance, ASCE, 2003, pp.34–43. Scholarly secondary history.
-
S15: Julius Weisbach, Lehrbuch der Ingenieur- und Maschinen-Mechanik, Volume 1, Theoretische Mechanik, Vieweg, 1845. The Internet Archive digitisation of the Bayerische Staatsbibliothek copy (identifier
10708309bsb) was text-checked 24 October 2026. The contents reference the pipe-flow chapter “Von dem Ausflusse des Wassers durch Röhren” at printed page 420; the chapter text begins on printed page 421. Section 329 at printed pages 431–432 discusses long-pipe wall friction and resistance; sections 330–331 at pages 433–434 contain the resistance-relation and empirical-coefficient discussion; section 332 at pages 435–436 sets out application cases. This closes the primary-text chapter and page-location subgap only. The scan typography and equation have not been visually inspected in this run, so no historical formula is transcribed or claimed verified. - S16: Institution of Civil Engineers, C. F. Colebrook, Turbulent flow in pipes, 1939, Journal of the Institution of Civil Engineers, volume 11(4), pp.133–156. The current publisher record, rechecked 24 October 2026, confirms the paper, issue, pagination and DOI, but provides only a first-page preview without subscription access to the full PDF. A separate openly searchable scan reproduction was text-checked solely as a locator: it places the new transition-formula discussion and equations (10)–(13), including formula (12), on printed page 140. Because that reproduction is not publisher-authenticated and the equation typography has not been independently visually verified, no historical formula is transcribed or approved. Do not substitute the separate correspondence listed as S17.
- S17: Institution of Civil Engineers, correspondence on Colebrook's paper, 1939, volume 12(8), pp.393–422. Kept separate from the original paper.
- S18: US Bureau of Reclamation, C. E. Brockway, Flow Resistance Coefficients of Three Sizes of Cast-in-Place Concrete Pipe, Laboratory Report Hyd-533, 1964. Used as a measured-data arithmetic audit with limitations retained.
- S19: US Bureau of Reclamation, Friction Factors for Large Conduits Flowing Full, Engineering Monograph No.7, revised reprint 1977. Historical large-pipeline scope and scatter retained.
- S20: NIST Digital Library of Mathematical Functions, section 3.3(ii), equation 3.3.14, two-node linear interpolation.
Practical design, installation and water-safety sources
- S21: Irrigation Association, Design Capacity & Available Pressure: workbook contents. Bibliographic reference only. This one-page contents document does not contain the design method and is not evidence for the flow or pressure guidance.
- S22: Hunter Industries, Residential Sprinkler System Design Handbook. Used as an introductory manufacturer reference for planning sequence, zones, valves and controls. Hunter scopes the handbook to small single-family residential sprinkler systems; it is not evidence for a larger commercial or sports-turf design.
- S23: Rain Bird, XF Series Dripline Design, Installation and Maintenance Guide. Used as a manufacturer reference for dripline planning, filtration, regulation, flushing and maintenance.
- S24: Rain Bird, CP/CPF Series Valve Installation and Operation. Used as a manufacturer example for valve direction, flushing, wiring, manual testing and fault isolation.
- S25: Water Regs UK, Hose union taps checklist, version 1.0, February 2024. Used for general UK backflow-risk and notification cautions. Local water-undertaker requirements take priority.
- S26: Department for Environment, Food and Rural Affairs, Water fittings regulations: specifications approved by the regulators. The 2026 backflow specification is recorded as published but does not come into effect until 6 May 2027.
Evidence status
Some sources are visually checked, some text checked and some bibliographic metadata only. Original Colebrook and Weisbach equation locations, parts of the EPANET transcription and the missing engineering evidence standard remain unresolved. Those gaps are not silently promoted.
Controls, sprinklers, pumps and seasonal-care sources
- S27: Hunter Industries, ICC2 Controller Quick Start Programming Guide. Used as a manufacturer example for programmes, start times, station run times and manual testing. Exact controls vary by model.
- S28: Hunter Industries, Wireless Rain-Clik Sensor Instructions. Used for general sensor status, bypass and functional-check cautions. The exact installed model and current model instructions take priority.
- S29: Hunter Industries, Standard MP Rotator Nozzle. Used as a manufacturer example of matched precipitation within that compatible nozzle family. It does not show that mixed families, models or operating pressures are matched.
- S30: Grundfos, Cavitation and Its Effects on Pumps. Used for general pump-inlet and cavitation cautions, not as a product-selection curve. Printed pages 1–5 were inspected. The US-unit worked example and fixed allowance are excluded from general Stockist copy; only the general cavitation mechanism and mitigation routes are used.
- S31: Rain Bird, Homeowner's Guide to Winterization. Used for general drainage and compressed-air safety principles. UK site conditions and exact component instructions take priority.
Manufacturer-document boundary: S22 to S24 and S27 to S31 are examples from named product families or manufacturers. They support general workflow and cautions but do not prove that another product has the same limits, controls or installation method.
Filtration, regulation and PVC identification sources
- S32: Rain Bird, Inline RBY and pressure-regulating filter performance information, plus the current official Inline RBY Filter and Pressure-Regulating Filter RBY product pages (rechecked 25 October 2026). The current pages identify RBY075MPTX and RBY100MPTX inline-filter operating ranges, and PRF-075-RBY and PRF-100-RBY flow and regulated-pressure ranges; these named-model ranges are usable as published. The current Inline RBY product page still embeds Rain Bird's 2018 pressure-loss chart image. Visual inspection confirms that image retains the same inconsistent flow-unit pairings as the linked PDF: its 1 gpm row is paired with 0.8 L/min, while the separate PRF table pairs 1 gpm with 3.8 L/min. A bounded official Rain Bird source search did not locate a corrected exact-model table. The inline pressure-loss rows therefore remain withheld as calculation inputs. Do not silently realign the printed columns or substitute another product's table.
- S33: Irrigation Association, Understanding Pressure Regulation. Used for general regulator performance, flow-range, inlet-pressure and installation principles.
- S34: Georg Fischer Piping Systems, Schedule 40 PVC dimensional data. Used only as an accountable example demonstrating that an imperial nominal size differs from actual outside diameter. It is not a UK system compatibility table.
Available flow and working pressure
- S35: Rain Bird, Irrigation Design Tip: Determining Water Supply Requirements, opening section. Supports the need to establish available flow and working pressure at the point of connection for that flow. Its meter examples and sizing rules are manufacturer design guidance, not a substitute for measured UK site conditions or a borehole pumping test.
Dimensional-data boundary: A single manufacturer table cannot identify every installed PVC system. Printed markings, accurate measurement and the current dimensional table for the exact pipe family remain necessary.
Source, intake, storage and pump-suction evidence
- S36: Hydraulic Institute, Understanding the 2024 Updates to ANSI/HI 9.6.1 Rotodynamic Pumps Guideline for NPSH Margin, 18 March 2025. Used for the distinction between system-specific NPSHA, manufacturer-specified NPSHR and application-specific margin considerations across the operating range. The full paid standard and its application tables were not inspected, so this source does not authorise a universal margin.
- S37: Environment Agency, Safe passage for eels, last updated 30 January 2024. England-only evidence for eel-passage and screening duties. For existing diversion structures, the page says a screen is required in most cases where at least 20 m³/day is abstracted; it is not a universal screen mesh, approach-velocity or design specification.
- S38: Environment Agency, Screening for intake and outfalls: a best practice guide, published 1 February 2005. Used for fish-screening risk, failure, monitoring and maintenance principles in section 4.1 and the section 6.1 operations sequence. The technical document was inspected at PDF pages 98 and 120. Its age and broad scope must remain visible; current licence conditions, current regulator advice and site-specific ecological requirements take priority.
- S39: AHDB Horticulture, How to assess and improve water quality. Used for horticultural sampling categories, source-sensitive interpretation and sampling-frequency context. Its annual or six-monthly wording is not a universal schedule or acceptance standard for every turf, landscape, crop, water source or treatment system.
- S40: British Geological Survey, Borehole records. Used for free GeoIndex access, record-content descriptions and the National Well Record Collection. Available neighbouring records do not establish complete coverage or guarantee a proposed site’s depth, geology, yield, water quality, permission or construction.
- S41: Environment Agency, Apply for consent to investigate a groundwater source, updated 29 April 2026. England-only evidence for the investigation-consent threshold of 20 m³/day or more, water-features surveys, pumping tests, groundwater-impact assessment and specialist hydrogeological advice. Finding a satisfactory yield does not guarantee an abstraction licence.
- S42: Water Regs UK, Alternative Water Supplies. Used for the physical-separation principle where mains and alternative water are present, including break-tank and Type AA/AB air-gap context. The guidance is informative and subject to change; the local water undertaker and competent designer determine the actual installation.
- S43: Water Regs UK, Cold Water Storage. Used for general access, turnover, stagnation, inlet controls, overflow and warning arrangements. It does not replace the exact tank manufacturer’s installation instructions, structural/base design or the local water undertaker’s decision.
- S44: Environment Agency, Abstract or impound water: hydrological information needed for your application, updated 29 August 2025. England-only evidence for flow variability, hydrographs, long-term statistics, validation and storage-reservoir context. It is not a universal irrigation-storage sizing method.
- S45: Environment Agency, Rainwater harvesting: regulatory position statement, updated 28 January 2021. England-only evidence distinguishing isolated harvested rainwater from systems mixed with surface water or groundwater. The statement says it is valid until April 2029 and must be rechecked before reliance.
Source checks: S36–S45 links and relevant source sections rechecked 12 October 2026. Scope and unresolved design dependencies are recorded in the Open Evidence Register.
Pipe-flow methods and system losses
- S46: USDA Natural Resources Conservation Service, National Engineering Handbook, Part 634 Hydraulics, Chapter 4: Pipe Flow, first edition, February 2022. The complete 76-page file was retrieved and relevant pages visually inspected on 16 October 2026. Checked locations: section 634.0403, printed pages 634-4.6–9 (Darcy-Weisbach and friction factor); 634.0405, pages 634-4.14–20 (local losses); 634.0406, pages 634-4.20–24 (pumps and system curves); 634.0410, pages 634-4.51–53 (water hammer); and 634.0411, from page 634-4.54 (cavitation). Sections 634.0413–14, pages 634-4.68–70, are sprinkler and microirrigation overviews that refer detailed design to other chapters. This is a US engineering reference, not UK regulation or approval of an installed system. Selected fitting coefficients, manufacturer examples and surge values must not be transferred without checking their conditions.
Two isolated worked-example calculations were reproduced within 0.25% of the printed results; see the Verification and Test Record. This does not release a customer calculator, product-specific dataset or site design.
England abstraction threshold clarification
- S47: Environment Agency, Check if you need a licence to abstract water, updated 2 July 2026 and rechecked 22 October 2026. England-only evidence for the general licence starting point: taking more than 20 m³ (20,000 litres) a day is likely to need a licence, while 20 m³ or less a day is listed as exempt when it forms one operation and the combined abstraction from multiple points on the same source stays within that limit. Read this with S41, which sets the separate groundwater-investigation consent threshold at 20 m³/day or more before an abstraction-licence application. Neither source removes other exemptions, regulatory position statements, impounding controls, local licensing strategy, licence conditions or project-specific advice.
Wales and Northern Ireland abstraction thresholds
- S48: Natural Resources Wales, Find out if you need a water abstraction or impoundment licence, rechecked 22 October 2026. Wales-only evidence that 20 m³/day or less does not need an abstraction licence and that taking water from inland water or groundwater needs a licence unless exempt. Impoundment is treated separately, and the page does not replace catchment availability, licence conditions, access rights or pre-application advice.
- S49: Department of Agriculture, Environment and Rural Affairs, Applying to Abstract or Impound Water, and the published Schedule 1 permitted controlled activities excerpt, rechecked 23 October 2026. Northern Ireland-only evidence: Schedule 1(2) covers less than 10 m³/day, while Schedule 1(3) separately covers between 10 and 20 m³/day and requires the operator to notify the Department. Exactly 10 m³/day therefore falls in the 10–20 band rather than the under-10 no-form band; DAERA's current page says an application form must still be submitted for abstractions between 10 and 20 m³/day. Monitoring, environmental-impact, fee and licence-condition requirements remain separate.
Scotland abstraction authorisation
- S50: Scottish Environment Protection Agency, current EASR water-activity guidance, rechecked 23 October 2026. SEPA's water-activities page says water-management activities have been regulated under the Environmental Authorisations (Scotland) Regulations 2018 since 1 November 2025. Its current abstraction pages place less than 10 m³ in any one day under a General Binding Rule when its conditions are met, require registration for inland-water abstraction from 10 to 50 m³/day inclusive, and require a permit for non-hydropower inland-water abstraction above 50 m³/day. This is Scotland-only starting-point evidence; the activity, source, purpose and any associated borehole, dewatering, impoundment or hydropower work can select a different SEPA route and conditions.
Manufacturer manuals and specifications
Browse by brand Hunter · Rain Bird · Netafim · Radius
Hunter
- DUAL decoder manual
- Hunter G-880 data
- Hunter ICV valve product and troubleshooting guide
- Hunter irrigation freeze-protection notes
- Hunter PGP Ultra specification
- Hunter Pro-Spray PRS30 check-valve data
- Hunter quick-coupler specification
- Hunter winterisation guidance
- X-Core manual
Rain Bird
- ESP-LXD manual
- FG100 information
- filter sizing data
- filtration design guide
- large-capacity filter data
- legacy Decoder System Manual
- Rain Bird 752 Series technical specification
- Rain Bird HDF 1X2 manual
- Rain Bird Landscape Irrigation Design Manual
- Rain Bird Maxi-Paw impact-sprinkler data
- Rain Bird sprinkler installation guide
- Rain Bird swing-joint specification
- Rain Bird TRU controller troubleshooting guide
- Rain Bird winterisation guidance
- Rain Bird: all zones watering more than intended
- Sprinkler Spacing and Design guidance
- swing-joint technical specification
- turf swing-joint information
Netafim
- disc-filter catalogue
- media-filter guidance
- Netafim DripNet PC technical specification
- Netafim pressure-compensating emitter technical data