Irrigation Asset and Equipment Schedule

An asset schedule identifies what is installed, where it is, what duty it performs and which evidence controls its maintenance or replacement. It is not a shopping list and should not contain guessed model numbers or SKUs.

Black irrigation valve, adjacent manual valve, pipe fittings and blue cable in an open excavation
A field valve, adjacent manual valve and control cable in an open excavation.

Use one stable asset identity

Give each significant item a unique site reference that appears on drawings, valve-box labels, controller schedules, commissioning records and service reports. Typical groups include source and meter, tank, pump, filter, treatment equipment, backflow arrangement, main isolation, controller, decoder interface, flow sensor, master valve and zone valve.

Minimum schedule fields

  • Asset reference, description, system and precise location.
  • Manufacturer, model and serial number only when read from reliable evidence.
  • Connection sizes and thread family, voltage or signal type, and pressure or flow duty.
  • Installed settings, firmware or programme reference where relevant.
  • Isolation points, safe access needs and stored-energy hazards.
  • Commissioning date, warranty evidence and current manual location.
  • Inspection or maintenance interval, last action, next action and responsible party.
  • Approved spare or replacement basis, with compatibility evidence.

Worked consistency check

If a commissioned zone contains 24 outlets recorded at 0.20 m³/h each, the scheduled total is 24 × 0.20 = 4.80 m³/h, equal to 80 L/min. Compare this with the measured zone flow under the same operating conditions. A difference does not identify the cause, but it flags a record, nozzle, pressure, leakage or measurement issue.

Record interfaces, not only components

Record how the pump is enabled, which valve is the master valve, which sensor input stops high flow, which filter protects which outlets and which electrical or communications panel controls the asset. A correct component can still fail as a system if an interface is undocumented.

Safety and limitations

Do not open electrical panels, pressure vessels, dosing equipment or backflow devices merely to complete a schedule. Use labels, manuals, commissioning documents and competent inspection. Asset data does not prove continued safety or suitability. Where equipment is used at work, inspection and maintenance duties may apply under PUWER or other legislation.

Related records and sources

Return to design and delivery