Spring Irrigation Recommissioning Checklist

Recommission slowly and measure before restoring automatic watering. A system that appears intact can still contain a split fitting, displaced seal, blocked outlet or unsafe electrical defect.

Sprinklers operating on a golf green during a controlled seasonal restart
Sprinklers operating during a controlled spring restart on a golf green.

Before admitting water

  • Compare the site with the shutdown record and as-fitted drawing.
  • Inspect exposed pipe, pumps, filters, valves, backflow components, test points and controller enclosures.
  • Confirm drains, test cocks and isolation valves are in the positions required by their current instructions.
  • Remove temporary insulation or covers without blocking vents, drainage openings or equipment cooling.
  • Keep the automatic programme disabled and prevent an unintended pump start.

Restore the hydraulic system

  1. Provide a safe route for displaced air and water.
  2. Open the supply slowly, following pump and backflow-device instructions.
  3. Inspect the mainline at low demand before operating zones.
  4. Run one zone at a time manually and check valve closure before moving on.
  5. Flush through designed points, then clean filters and inspect emitters or nozzles.
  6. Record dynamic pressure, zone flow and any meter movement when all controlled demand is off.

Worked flow check

If a verified meter increases by 0.84 mยณ during a 15-minute zone test, the average flow is 0.84 ร— 60 รท 15 = 3.36 mยณ/h, equal to 56 L/min. Compare this with the commissioned or design value under equivalent operating conditions. A difference is a prompt to investigate, not proof of one particular fault.

Controls and sensors

Use the controller station schedule to check date, time, start times, station run times, seasonal adjustment, rain or soil sensor status, master-valve logic, pump-start interlocks and high-flow shutdown. Prove alarms and remote notifications where fitted. Do not open mains-powered equipment or bypass a protective device unless competent and authorised.

Acceptance record

Record leaks repaired, components replaced, pressure and flow readings, filter condition, outlet faults, sensor tests, programme changes and any section not tested. Photograph vulnerable above-ground assemblies for comparison next winter.

Limitations and safety

Do not pressurise a visibly split, frozen or unsupported component. Isolate electrical equipment showing water entry, burning, corrosion or damaged cables. This checklist does not replace manufacturer instructions, a backflow test, electrical inspection or competent repair.